MULTI-BIOMETRIC

Multi-biometrics — verification, identification and assurance

Face, fingerprint, iris, palmprint and palm vascular are modeled as distinct modalities selected by device, quality, risk and policy; score-level fusion is not claimed without implementation evidence.

◈
SOURCEAuthoritative / document
◈
CAPTUREDevice / SDK
◈
VERIFYDocument + biometric
◈
ASSUREPolicy + risk
◈
DECIDEClaims / status
◈
EVIDENCEAudit / trace
Technical basisSOURCE-BACKED
SourceCheckID CheckID + ISO standards register
StandardISO/IEC 19795 + modality standards
VersionCurrent published edition per standard
ApplicabilityModality-specific; implementation dependent
EvidenceProcess types + standards mapping + certificate scope
TECHNICAL REFERENCE

Multi-biometric: multi-modality orchestration is not automatically fusion

Availability → modality selection → quality → per-modality result → policy combination

Workflow level

If a policy sequentially requests face, fingerprint or iris, this is multi-modal workflow orchestration. It is not automatically score-level or feature-level fusion.

Feature-level fusion

Claimed only when an engine combines feature representations before matching and a primary source confirms it.

Score-level fusion

Claimed only when matcher scores are normalized/combined through a documented rule or model.

Decision-level fusion

Claimed only when multiple modality decisions are combined into a policy-defined decision.

Fallback

An unavailable sensor or low-quality sample may lead to an alternate modality only when policy/source supports that behavior. Multiple available modalities do not imply automatic fallback.

Evidence

Evidence should preserve modality, capture/source, result and combination policy so an auditor knows which modalities contributed rather than receiving only “multibiometric passed”.

BIOMETRIC ARCHITECTURE

Modality, operation, quality, matching and performance are separate layers

Face, fingerprint, iris, palmprint and palm vascular do not share one operating envelope. “Supported/tested” is used only when matching engine/device/profile evidence exists.

Dimension Face Fingerprint Iris Palm
Capture concern Pose/illumination/occlusion/live context Sensor/profile/segmentation/finger configuration Focus/segmentation/occlusion/single-both eye Surface ROI or vascular sensor path
Operation 1:1 / 1:N where supported Enroll / 1:1 / 1:N / dedup where supported Enroll / 1:1 / 1:N where supported Actual product profile
Performance proof Test-context bound Test-context bound Test-context bound Test-context bound

Operating profile

Every claim about devices, thresholds, capture conditions or model versions maps to test/profile evidence; a vendor datasheet is not Mobile-ID compatibility evidence.

Verification vs identification

1:1 compares a probe with a known reference; 1:N searches a gallery. FMR/FNMR do not replace FPIR/FNIR and gallery context.

PAD vs matching

PAD measures presentation-attack handling; matching measures recognition/similarity. APCER/BPCER are not face-matching accuracy metrics.

Multi-biometric

Fusion is used only when feature-, score- or decision-level fusion is source-backed; sequential modality workflows are not automatically fusion.